OK
PAY ONLINE
CASH ON DELIVERY
Note: This product is currently not available.
The product name
$ 150,000
If you wish to buy more than one quantity of this product, please add the desired quantity in the next step.
PROCEED TO PAYMENT
After clicking the button, you will be redirected to a separate page.
YOUR DETAILS
ORDER DETAILS
this is the product name that is to be bought
$ 1200
QTY
Note: The delivery usually takes 2-5 days depending on availability and your location.
12
12

Order Summary

3 Products

 1,234

View Cart
MORE
Come browse our
Products
Page 3 of 3.11
EAPL FAULT ANUNCIATORS
EAPL FAULT ANUNCIATORS
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs
VIEW DETAILS ADD TO CART
EAPL DC MULTI FUNCTION ME
EAPL DC MULTI FUNCTION METER
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Micro Controller based 3 Channel DC Energy Meter. Displays DC parameters V, I, KW, KWh ,MWh& Load on hours of all three channels. Displays one set old Energy readings and Communication status. Display Hold / Scroll Facility available. Programmable Shunt ratios. Alphanumeric display for Parameter & values RS-485 serial port with Modbus RTU output. Wide Input Voltage and Current Range. Protection from dust and water as per IP-51. Dimensions: Overall:96 x 96 x 117mm (W x H x D) , Cutout: 92 x 92mm(W x H) Applications: DC rectifier systems, Battery panels, DC distribution solar panels,DC loads,DC motors etc Ordering Information: Model Function Source Voltage Input Voltage Parameter Data Sheet Regular SNM-01 DC Energy meter 110-240V AC/DC +/-10% 80V DC to 220V DC Page 1 (load1) V, A, KW, KWh,MWh,LH Click Here Page 2 (load 2) V, A, KW, KWh,MWh,LH Page 3 (load 3) V, A, KW, KWh,MWh,LH Page 4 (Old) KWh,MWh,LH (load 1, Load 2, load 3) Page 5 (Communication ) Communication status, Dev Id SNM-02 24-48V DC +/-10% 21V DC to 50V DC Page 1 (load1) V, A, KW, KWh,MWh,LH Page 2 (load 2) V, A, KW, KWh,MWh,LH Page 3 (load 3) V, A, KW, KWh,MWh,LH Page 4 (Old) KWh,MWh,LH (load 1, Load 2, load 3) Page 5 (Communication ) Communication status, Dev Id SNM-03 110 to 240V AC/DC+/-10% 5V to 1000V Voltage,Current,Wattage,Energy,Energy,Load Hours,Old Energy,Old Energy,Old Load Hours,DEVICE-ID & Comm. Status V, A, KW, KWh,MWh,LH,Old KWh,Old MWh,Old LH,Communication Status
VIEW DETAILS ADD TO CART
EAPL ENERGY MANAGEMENT SY
EAPL ENERGY MANAGEMENT SYSTEM
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: EMS-18: VAF Meter with True RMS Sensing, High brightness red LED display On site programmable CT(pri &sec) ratio Protection from dust and water as per IP-51 for front facia Measurement of basic parameters Program enable /disable facility available EMS-11: Measurement of current parameters (L-N) *CT primary and secondary programmable. EMS-12: Measurement of voltage parameters *PT primary and secondary programmable. EMS-13: Measurement of frequency parameter. EMS-14: Measurement of Power Factor parameter. EMS-02: Measurement of basic parameters.(Current (L-N), Voltage (L-N),(L-L), frequency (average) and Power factor (Total) * CT ratio programmable, RS485 Mod-bus RTU protocol available, Sensing : True RMS . Program can be locked by removing short link connected across specified terminals Hold/Scroll Facility available . Dimensions: For EMS-11,EMS-12,EMS-13,EMS-14 Overall: 96 x 96 x 97.5mm (W x H x D) * Cutout : 92 x 92mm (W x H) For EMS-02,EMS-18 Overall: 96 x 96 x 117 mm (W x H x D) * Cutout : 92 x 92mm (W x H) Applications: Sub metering, machines, Panels, power analysis systems etc. Ordering Information: Model Function Source Voltage Parameter Datasheet Regular EMS-11 Ammeter 240V AC -15% to +10% A(R, Y, B) Click Here EMS-12 Voltmeter V (R, Y, B), V(RY, YB, BR) EMS-13 Frequency Meter Hz. (Avg) EMS-14 Power Factor Meter 85V-270V AC/DC PF(R,Y,B), TPF EMS-18 VAF Meter V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz Click Here EMS-02 VAF / PF Meter V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz, PF(T)
VIEW DETAILS ADD TO CART
EAPL DIGITAL TIMER H/C/E
EAPL DIGITAL TIMER H/C/E SERIES
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Din Sized enclosuer for panel mounting. Digital dual display for set value and process value. FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE. TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS. One of the relay c/o can be configured as INSTANT or DELAYED. Program lock is provided for function, relay configuration, type of start signal and range selected. RESET cum START facility can be achieved either through front buttons Or Rear terminals HOLD/RESTART facility during power failure conditions. Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal Dimensions: Over-all: H3PT-MU – 48 x 48 x 115mm, C3PT-MU, CD6 - 72 x 72 x 128mm, E3PT-MU – 96 x 96 x 117mm (W x H X D) Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, CD6 - 69 x 69mm, E3PT-MU – 92 x 92mm (W x H) Applications: Injection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc Ordering Information: Model Function Source Voltage Time Selection Output Data Sheet Regular E3PT-MU Multifunction Up-counting 85V AC to 270V AC / DC 0.1secs to 99hrs 59mins 1c/o Instant, 2 c/o Delayed or 3 c/o Delayed Click Here H3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed C3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Optional H3PT-MU Multifunction 12V DC /24V DC 0.1secs to 99 hrs 59mins 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Contact Us CD6 ON-Delay with Instant contact 85V AC to 270V AC / DC 1 sec to 999mins 1c/o Instant, 1 c/o Delayed
VIEW DETAILS ADD TO CART
EAPL DIGITAL LCD TACHOMET
EAPL DIGITAL LCD TACHOMETER
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Micro-controller based design with world class Indian software. Non-contact sensing through reflected light beam on reflective sticker. LCD display Input sensing indication through LED. Memory facility to retain measured value. Portable, lightweight, strong and elegant ABS enclosure. Accuracy: 1RPM up to 5,000 RPM and 0.05% of the reading above 5,000 RPM. Resolution: 0.1RPM up to 5,999 RPM and 1RPM at and above 6,000RPM. Calibration certificate provided along with tachometer - traceable to national and international standards. Dimensions: Over-all: 72 X 170 X 38mm (W X H X D). Applications: Motors, Pumps, Generators, Engines and many more Ordering Information: Model Function Source Voltage Range Data Sheet DT 2001 B Digital Hand Held Non Contact Tachometer 6V DC (4x1.5V, 'AA' size Batteries) 1 to 99,999 RPM (with one reflecting mark) Click Here
VIEW DETAILS ADD TO CART
EAPL TIMER A1D1-X
EAPL TIMER A1D1-X
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Din sized enclosure for Track (Din rail) / Screw mounting. Front terminal protective cover for safety. LED indication for timing in progress. A1DA :External (zero volt / potential free) command contact for timing initiation. Dimensions: Over-all: 22.5 X 75 X 102mm (W X H X D). Applications: AMF panels, Automation panels, HT / LT panels, MCC panels, C & R panels, RTCC panels, Transformer panels and many more Model Function Source Voltage Time Range Output CSA Approved CE Approved Data Sheet Regular A1D1 On-Delay 240V AC 0.3 Secs to 30 Mins. 2 c/o Relay √ √ Click Here A1D1-X On-Delay X-Version* 0.3 Secs to 30 Mins. 2 c/o Relay √ √ A1D1-X (60M) On-Delay X-Version* 0.6 Secs to 60 Mins. 2 c/o Relay √ √ A1DE-X Interval X-Version* 0.3 Secs to 30 Mins. 2 c/o Relay √ √ A1DCS-X Equal Off/On Cyclic X-Version* 0.6 Secs to 60 Mins. 2 c/o Relay √ - A1DN-X Auxiliary Relay X-Version* 20 mSecs 2 c/o Relay √ √ A1D1 On-Delay 8V to 30V DC 0.3 Secs to 30 Mins 2 c/o Relay - Click Here A1D1(WB) On-Delay (Wide Band) 266V to 456V AC 3 Secs to 30 Secs 1 c/o Relay - - A1DA Signal Off-Delay 110V AC / 240V AC 0.3 Secs to 30 Mins 1 c/o Relay - - A1DS Star-Delta 110V AC / 240V AC / 415V AC 0.6secs to 60secs, #TD 40ms / 100ms 1 c/o (C-NO) Star, 1 c/o (C-NO) Delta - - A1DH-1 Power Off-Delay 240V AC** 18 Secs to 180 Secs 2 c/o Relay - - Optional A1D-E Interval 8-30V DC 0.3secs to 30mins 2 c/o Relay - - Contact Us A1DN-X(80mS) Auxilliary Relay X-Version * 80msecs 1 c/o Relay - - A1DA Signal Off-Delay 24V DC 0.3secs to 30mins 2 c/o Relay - - A1DS Star-Delta 240V AC , 60Hz / 24V DC 0.6secs to 60secs, #TD 40ms/100ms 1 c/o (C-NO) Star, 1 c/o (C-NO) Delta - - A1DH-1 Power Off-Delay 24V DC **/ 240V AC** 0.6secs to 6secs 2 c/o Relay - - *X-Version: 24V AC to 240V AC, 24V DC to 220VDC, **Minimum 2secs of aux, supply required for each cycle, else timer may malfunction #TD- Transfer Delay time to change from star to delta
VIEW DETAILS ADD TO CART
EAPL DIGITAL TEMPERATURE
EAPL DIGITAL TEMPERATURE CONTROLLER
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Universal Input (J,K,PT-100) Selectable. Wide Voltage Range. ON / OFF or Self-Tuned Function Selectable. Single / double set point. Over Voltage Protection Compensation offset feature available in TX7-Ua User Friendly Programming through increment / decrement button (TX7-ua) Indication for sensor, funtion and relay status. Program enable / disable for sensor, function, hystersis, compensation features in TX7-Ua. Dimension 72x72x128.5 Dimensions: Overall: H3-TX Models -48 x 48 x 115mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D) Cut-out: H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H) Ordering Information: Model Function Source Voltage Sensor Range Output Data Sheet Regular 85-270V AC / DC H3TX-2H-U 2 set point temp.controller (Heater Type) J K PT-100 (ON-OFF) 0°C - 600°C 0°C - 1200°C 0°C - 300°C 2 relay 1 c/o, 5A Click Here TX7-2H-U EX9-2H-U H3TX-2A-U 2 set point temp.controller (Alarm Type) TX7-2A-U EX9-2A-U *Function applicable only for H3TX-Ua, TX7-Ua, EX9-Ua, H3TX-2U, TX7-2U, EX9-2U and H3TX-Ub ** Offset applicable only for H3TX-Ua, TX7-Ua, EX9-Ua, H3TX-Ub
VIEW DETAILS ADD TO CART
EAPL ELECTRONIC TIMER H S
EAPL ELECTRONIC TIMER H SERIES
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: LED indication for timing in progress Front protective cover for safety. Timer and base available for Track(except H3D1). Large transparent knob with lock is provided for precise time setting and protect from unintentional change of time setting. H1DA-X : Accepts any voltage from 12V AC/DC to 240V AC / 220V DC as signal between command contacts for timing initiation. H1D1-X, H3D1: Multifunction-On-Delay / Interval / Equal Cyclic-On / Equal Cyclic-Off programmable. Dimensions: Over-all: 48 X 48 X 94mm (W x H x D) Cut-out: 46 X 46mm (W x H) Applications: Textile machines, Vending machines and many more… Ordering Information: Model Function Source Voltage Time Selection Output CSA Approval Data Sheet Regular H1DT-10 On-Delay (11 Pin) plug in type X-Version* 1sec to 10secs 2 c/o Relay √ Click Here H1DT-30 3secs to 30secs √ H1DT-60 6secs to 60secs √ H4DT-10 On-Delay (8 pin) plug in type 1sec to 10secs - H4DT-30 3secs to 30secs - H4DT-60 6secs to 60secs - H3D1 Multifunction (8 terminals) screw type 0.3secs to 60mins - Click Here H1D1-X Multifunction (11 Pin) plug in type 0.3secs to 60mins √ H1DA-X Signal Off-Delay (11 Pin) plug in type 0.6secs to 60mins √ *X-Version:24V AC to 240V AC, 24V DC to 220V DC
VIEW DETAILS ADD TO CART
EAPL  SEQUENTIAL TIMERS
EAPL SEQUENTIAL TIMERS
INR 0
INR 0 (Save NaN%)
Not Available | Free Shipping
Product Features: Suitable for screw mounting(except ST4-M1). 7 segment display indication for channel and timing operation (except ST-4M1). User friendly programming for ON/OFF time selection independently (except ST-4M1). Hold /Restart feature is available during power failure, Over voltage protection(except ST-4M1). ST-6M1 / ST-10M2 / ST-10M1 : pulse start signal. ST-15M2 / ST-4M1 : continuous start signal. S1D-C8M3 : Comprises of 8 Relays and each relay can be programmed for maximum of 8 switchings in a cycle. Potential free (Zero volts) continuous start signal and continuous signal from differential pressure switch is mandatory for operating the timer. Dimensions: Over-all: ST6-M1 / ST6-M2 / ST10-M2 / ST15-M2 / S1DC8-M3 – 200 x130 x 45mm , ST4-M1: 110 x 86 x 68mm (W x H x D) ,ST10-M1 (IP) / ST10-M2 (IP) / ST6-M1 (IP) / ST6-M2 / ST15-M2 – 291 x 214 x 82mm (W x H x D). Applications: Bag Filter systems, dust pollution systems, Air handling systems, MCC panels, conveyors, process industries, and many more
VIEW DETAILS ADD TO CART