http://WWW.SVESLUDHIANA.IN
SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'decrement button'
EAPL DIGITAL TIME SWITCH INR   0 INR  0
-NaN%

EAPL DIGITAL TIME SWITCH

Product Features: Switches On and Off 4 times in a day with respect to real time. LED indication for relay status, LCD display for real time clock. User friendly programming with manual over ride facility. Clock hour and Clock minute buttons can be enabled by shorting terminals to program RTC. For TS-203, TS-203B : Use (1.5Vx2)AA size Batteries Dimensions: TS-203 :Over-all:72 x 72 x 84mm (W x H x D) TS-203B : Over-all:110 x 86 x 68mm (L x W x D) Applications: Street lightings,advertising sign boards etc Ordering Information: Model Function Source Voltage Output Data Sheet TS-203 Digital Daily 4 program time switch 240V AC 1 C/O Relay,16A Click Here TS-203B Digital Daily 4 program time switch 240V AC 1 C/O Relay,16A

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TIMER H/C/E SERIES INR   0 INR  0
-NaN%

EAPL DIGITAL TIMER H/C/E SERIES

Product Features: Din Sized enclosuer for panel mounting. Digital dual display for set value and process value. FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE. TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS. One of the relay c/o can be configured as INSTANT or DELAYED. Program lock is provided for function, relay configuration, type of start signal and range selected. RESET cum START facility can be achieved either through front buttons Or Rear terminals HOLD/RESTART facility during power failure conditions. Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal Dimensions: Over-all: H3PT-MU – 48 x 48 x 115mm, C3PT-MU, CD6 - 72 x 72 x 128mm, E3PT-MU – 96 x 96 x 117mm (W x H X D) Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, CD6 - 69 x 69mm, E3PT-MU – 92 x 92mm (W x H) Applications: Injection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc Ordering Information: Model Function Source Voltage Time Selection Output Data Sheet Regular E3PT-MU Multifunction Up-counting 85V AC to 270V AC / DC 0.1secs to 99hrs 59mins 1c/o Instant, 2 c/o Delayed or 3 c/o Delayed Click Here H3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed C3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Optional H3PT-MU Multifunction 12V DC /24V DC 0.1secs to 99 hrs 59mins 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Contact Us CD6 ON-Delay with Instant contact 85V AC to 270V AC / DC 1 sec to 999mins 1c/o Instant, 1 c/o Delayed

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TEMPERATURE CONTROLLER INR   0 INR  0
-NaN%

EAPL DIGITAL TEMPERATURE CONTROLLER

Product Features: Universal Input (J,K,PT-100) Selectable. Wide Voltage Range. ON / OFF or Self-Tuned Function Selectable. Single / double set point. Over Voltage Protection Compensation offset feature available in TX7-Ua User Friendly Programming through increment / decrement button (TX7-ua) Indication for sensor, funtion and relay status. Program enable / disable for sensor, function, hystersis, compensation features in TX7-Ua. Dimension 72x72x128.5 Dimensions: Overall: H3-TX Models -48 x 48 x 115mm, TX7 Models- 72 X 72 X 128mm; EX9 Models- 96 x 96 x 117mm (W x H X D) Cut-out: H3-TX Models – 46 x 46mm, TX7 Models - 69 x 69mm , EX9 Models – 92 x 92mm (W x H) Ordering Information: Model Function Source Voltage Sensor Range Output Data Sheet Regular 85-270V AC / DC H3TX-2H-U 2 set point temp.controller (Heater Type) J K PT-100 (ON-OFF) 0°C - 600°C 0°C - 1200°C 0°C - 300°C 2 relay 1 c/o, 5A Click Here TX7-2H-U EX9-2H-U H3TX-2A-U 2 set point temp.controller (Alarm Type) TX7-2A-U EX9-2A-U *Function applicable only for H3TX-Ua, TX7-Ua, EX9-Ua, H3TX-2U, TX7-2U, EX9-2U and H3TX-Ub ** Offset applicable only for H3TX-Ua, TX7-Ua, EX9-Ua, H3TX-Ub

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1
false