http://WWW.SVESLUDHIANA.IN
SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'fault'
EAPL SMPS INR   0 INR  0
-NaN%

EAPL SMPS

Product Features: Compact, light weight and SMPS design Versatile and easy snap-on mounting on Din-rail Very low ripple and noise Regulated and adjusted output Protection against over voltage, short circuit and over load. Dimensions: Overall: MS-01 - 45 x 75 x 116mm, MS-02 – 110 x 86 x 71mm , MS-03 - 155 x 88 x 79mm, MS-04 - 172x150x78mm MS-05 – 22.5 x 75 x 97mm (W x H x D) Applications: PLC, DC Panels, DC Solenoids, DC Relay boards, Battery Charging Panels, etc. Ordering Information: Model Function Source Voltage Output Data Sheet Voltage Ampere Watt Regular MS-01 Switch Mode Power Supply 192V-264V AC 24V DC 1A 24W Click Here 12V DC 1A 12W MS-02 Switch Mode Power Supply 170V-300V AC 24V DC 0.63A 15W Click Here 24V DC 1.04A 25W 24V DC 1.46A 35W 24V DC 2.1A 50W 12V DC 1.25A 15W 12V DC 2.08A 25W 12V DC 2.9A 35W 12V DC 4.2A 50W 5V DC 6A 30W MS-03 Switch Mode Power Supply 170 – 300V AC 24V DC 5A 120W Click Here MS-05 Switch Mode Power Supply 170 – 300V AC 5V DC 1A 5W Click Here Optional MS-04 Switch Mode Power Supply 190V-270V AC 24V DC 10A 240W Contact Us Electronic Timers A-Series B-Series Digital Timers H-Series S-Series Programmable Fault Annunciator

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1
false