http://WWW.SVESLUDHIANA.IN
SVES 59d3c289767a2d0b30e5c34d False 75 28
OK
background image not found
Found results for
'terminals'
EAPL DIGITAL TIME SWITCH INR   0 INR  0
-NaN%

EAPL DIGITAL TIME SWITCH

Product Features: Switches On and Off 4 times in a day with respect to real time. LED indication for relay status, LCD display for real time clock. User friendly programming with manual over ride facility. Clock hour and Clock minute buttons can be enabled by shorting terminals to program RTC. For TS-203, TS-203B : Use (1.5Vx2)AA size Batteries Dimensions: TS-203 :Over-all:72 x 72 x 84mm (W x H x D) TS-203B : Over-all:110 x 86 x 68mm (L x W x D) Applications: Street lightings,advertising sign boards etc Ordering Information: Model Function Source Voltage Output Data Sheet TS-203 Digital Daily 4 program time switch 240V AC 1 C/O Relay,16A Click Here TS-203B Digital Daily 4 program time switch 240V AC 1 C/O Relay,16A

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL FAULT ANUNCIATORS INR   0 INR  0
-NaN%

EAPL FAULT ANUNCIATORS

Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm,M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL ENERGY MANAGEMENT SYSTEM INR   0 INR  0
-NaN%

EAPL ENERGY MANAGEMENT SYSTEM

Product Features: EMS-18: VAF Meter with True RMS Sensing, High brightness red LED display On site programmable CT(pri &sec) ratio Protection from dust and water as per IP-51 for front facia Measurement of basic parameters Program enable /disable facility available EMS-11: Measurement of current parameters (L-N) *CT primary and secondary programmable. EMS-12: Measurement of voltage parameters *PT primary and secondary programmable. EMS-13: Measurement of frequency parameter. EMS-14: Measurement of Power Factor parameter. EMS-02: Measurement of basic parameters.(Current (L-N), Voltage (L-N),(L-L), frequency (average) and Power factor (Total) * CT ratio programmable, RS485 Mod-bus RTU protocol available, Sensing : True RMS . Program can be locked by removing short link connected across specified terminals Hold/Scroll Facility available . Dimensions: For EMS-11,EMS-12,EMS-13,EMS-14 Overall: 96 x 96 x 97.5mm (W x H x D) * Cutout : 92 x 92mm (W x H) For EMS-02,EMS-18 Overall: 96 x 96 x 117 mm (W x H x D) * Cutout : 92 x 92mm (W x H) Applications: Sub metering, machines, Panels, power analysis systems etc. Ordering Information: Model Function Source Voltage Parameter Datasheet Regular EMS-11 Ammeter 240V AC -15% to +10% A(R, Y, B) Click Here EMS-12 Voltmeter V (R, Y, B), V(RY, YB, BR) EMS-13 Frequency Meter Hz. (Avg) EMS-14 Power Factor Meter 85V-270V AC/DC PF(R,Y,B), TPF EMS-18 VAF Meter V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz Click Here EMS-02 VAF / PF Meter V(R, Y, B), V(RY, YB, BR), A(R,Y, B), Hz, PF(T)

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL DIGITAL TIMER H/C/E SERIES INR   0 INR  0
-NaN%

EAPL DIGITAL TIMER H/C/E SERIES

Product Features: Din Sized enclosuer for panel mounting. Digital dual display for set value and process value. FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE. TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS. One of the relay c/o can be configured as INSTANT or DELAYED. Program lock is provided for function, relay configuration, type of start signal and range selected. RESET cum START facility can be achieved either through front buttons Or Rear terminals HOLD/RESTART facility during power failure conditions. Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal Dimensions: Over-all: H3PT-MU – 48 x 48 x 115mm, C3PT-MU, CD6 - 72 x 72 x 128mm, E3PT-MU – 96 x 96 x 117mm (W x H X D) Cut-out: H3PT-MU – 46 x 46 mm, C3PT-MU, CD6 - 69 x 69mm, E3PT-MU – 92 x 92mm (W x H) Applications: Injection moulding machine panels, Granite processing machines, Packaging / Printing machines, Hot stamping machines etc Ordering Information: Model Function Source Voltage Time Selection Output Data Sheet Regular E3PT-MU Multifunction Up-counting 85V AC to 270V AC / DC 0.1secs to 99hrs 59mins 1c/o Instant, 2 c/o Delayed or 3 c/o Delayed Click Here H3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed C3PT-MU 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Optional H3PT-MU Multifunction 12V DC /24V DC 0.1secs to 99 hrs 59mins 1c/o Instant, 1 c/o Delayed or 2 c/o Delayed Contact Us CD6 ON-Delay with Instant contact 85V AC to 270V AC / DC 1 sec to 999mins 1c/o Instant, 1 c/o Delayed

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL ELECTRONIC TIMER H SERIES INR   0 INR  0
-NaN%

EAPL ELECTRONIC TIMER H SERIES

Product Features: LED indication for timing in progress Front protective cover for safety. Timer and base available for Track(except H3D1). Large transparent knob with lock is provided for precise time setting and protect from unintentional change of time setting. H1DA-X : Accepts any voltage from 12V AC/DC to 240V AC / 220V DC as signal between command contacts for timing initiation. H1D1-X, H3D1: Multifunction-On-Delay / Interval / Equal Cyclic-On / Equal Cyclic-Off programmable. Dimensions: Over-all: 48 X 48 X 94mm (W x H x D) Cut-out: 46 X 46mm (W x H) Applications: Textile machines, Vending machines and many more… Ordering Information: Model Function Source Voltage Time Selection Output CSA Approval Data Sheet Regular H1DT-10 On-Delay (11 Pin) plug in type X-Version* 1sec to 10secs 2 c/o Relay √ Click Here H1DT-30 3secs to 30secs √ H1DT-60 6secs to 60secs √ H4DT-10 On-Delay (8 pin) plug in type 1sec to 10secs - H4DT-30 3secs to 30secs - H4DT-60 6secs to 60secs - H3D1 Multifunction (8 terminals) screw type 0.3secs to 60mins - Click Here H1D1-X Multifunction (11 Pin) plug in type 0.3secs to 60mins √ H1DA-X Signal Off-Delay (11 Pin) plug in type 0.6secs to 60mins √ *X-Version:24V AC to 240V AC, 24V DC to 220V DC

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
EAPL TIMER- B1DCA-T INR   1350 INR  1350
-0%

EAPL TIMER- B1DCA-T

Product Features: Din sized enclosure for Track (Din rail) / Screw mounting. B1DCA-T : HOLD / RESTART facility during power fail conditions. B1DCA-T : Auto / Manual switch for mode of operation B1DCA-T : Program - enable / disable facility for tamper proof operation. B1DCA-X, B1DCA-T : Independently selectable ON & OFF time. SPP-T :Trips under phase missing, phase reversal or phase unbalance In manual mode, terminals provided to connect to switch so as to manually switch ON and switch OFF load Dimensions: Over-all: 45 X 75 X 116mm (W X H X D).

INR 1350 INR 1350

Availability:True

Pay mode:COD only

view details
1
false