http://WWW.SVESLUDHIANA.IN
SVES 59d3c289767a2d0b30e5c34d False 83 58
OK
background image not found
Found Update results for
'digital motor protection relays'
9
Programmable Anunciators Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL for Alarm Anunciators Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm, M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs
Electronic Timers A-Series B-Series Digital Timers H-Series S-Series Programmable Fault Annunciator Pre-Set Counters Energy Management System Basic Meters Multi-Function Meters DC Multifunction Meters Maximum Demand Controller Converter Monitoring & Motor Protection Devices Digital Monitoring devices Analog Monitoring Device Motor Protection Relay Temperature Controllers Dual Set Point Single Set Point Power Supply Modules Tachometer Time Switch Light Switch Solar Charge Controllers ACDB AJB Box Interface Relay Module Photo Relay
THERMISTER PROTECTION UNITS TP01 AND TP04 FOR MOTOR PROTECTION USED IN TEXTILE MACHINES
Thermister Protection control Unit TPU04 & TPU06 Thermister Sensors for Motor Protection & for Blow Room & Carding Machines
◦ EAPL PRODUCTS RANGE ◦ Electronic Timers ◦ Programmable Fault Annunciator ◦ Pre-Set Counters ◦ Energy Management System ◦ Monitoring & Motor Protection Devices ◦ Temperature Controllers ◦ Power Supply Modules ◦ Tachometer ◦ Time Switch ◦ Interface Relay Module ◦ Light Switch ◦ Solar Charge Controllers ◦ Photo Relay
We are Authorised Dealer for EAPL -Electrinic Timer , Analog Timers , Counter , Digital Tachometers , Digital Temperature Controller, Energy Management Systems , Relay Interface Modules , Solar D B Panels
DIGITAL PANEL METERS--CADEL , ELTRAC , RISHABH , CONZERV DIGITAL INSTRUMENTS-FLUKE , KUSUM MECO , KEW DIGITAL PH METERS , TDS METERS , CONUCTIVITY METERS ELECTROMAGNETIC FLOW METERS LEVEL AND FLOW SWITCHES
EAPL Digital LCD Tachometer , Alarm Anunciators & Timers
PTC THERMISTER SENSORS FOR ELECTRIC MOTORS
1
false