http://WWW.SVESLUDHIANA.IN
http://WWW.SVESLUDHIANA.IN

Checking delivery availability...

background-sm
Search
3

Updates found with 'fault annunciators'

Page  1 1

Updates found with 'fault annunciators'

Programmable Anunciators Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL for Alarm AnunciatorsProduct Features: Sleek, light weight, ABS enclosureSuper bright, Red color SMD, LED for fault indicationsTest / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.Multiple units terminals can be connected in parallel to achieve more windowsEach window can be programmed for fault inputs as NO or NC and output as alarm or tripAbove program can be locked by removing the short link across specified terminalsOver voltage protectionBasic Models: M2-2 / M2-4 / M2-6 / M2-8Advanced Models: M2-12 / M2-16 / M2-24Available in 12, 16 and 24 windows respectivelyAvailable in wide auxiliary voltage range of 85-270V AC/DC.Advanced Models with additional features: M2-12R / M2-16R / M2-24RRS485 output signals are available for displaying Fault and healthy status of each window.Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window.Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D)Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm, M2-12, M2-16, M2-24: 285 x 181mm(W x H)Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc.Ordering Information: Model No. of Windows Function Source Voltage Output Input Data SheetRegularM2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click HereM2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputsM2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputsM2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputsM2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click HereM2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputsM2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputsOptionalM2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact UsM2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputsM2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputsM2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputsM2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputsM2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputsM2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs
Send Enquiry
Read More
G / E-SeriesDigital Monitoring devicesYou are hereHOME » PRODUCTS » MONITORING & MOTOR PROTECTION DEVICES » G / E-SERIES Product Features: Front button for resetting in manual modeExternal potential free (zero volt /no voltage) terminal contacts for auto mode.LED indication for relay statusWindow displays the type of fault that has occurred during unhealthy conditionTrip delay time and limits for each parameter can be set digitallyAll programs can be locked by removing short link across specified terminalsUnwanted parameters can be by-passed as per user's choice.Relay can be configured to have NO or NC status during healthy conditionUnit will retain fault till accepted in manual modePVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.Displays all the 3 phase voltages in a scrolling fashion during healthy condition.PVMD – Panel / Flush mounting, PVMD-G Din Rail mountingPVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current)Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.User can set the in-rush time delay.Terminals to connect all the 3 phase CTs are provided.CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5.PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mountingDin sized enclosure with Auto / manual SwitchDimensions: Overall: PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G, – 76 x 78 x 115mm (W x H x D)Cut-out: PVMD, PVIMD– 92 x 92mm (W x H)Applications: Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators, etcOrdering Information: Model Function Input voltage Output Data SheetPVMD Phase Voltage Monitoring Device 415V AC 3phase, 4 wire, Self powered 1 c/o, 10A Click HerePVMD - G Phase Voltage Monitoring DevicePVIMD Phase Voltage Current Monitoring DevicePVIMD - G Phase Voltage Current Monitoring Device
Send Enquiry
Read More
Page 1 0.5