http://WWW.SVESLUDHIANA.IN
http://WWW.SVESLUDHIANA.IN

Checking delivery availability...

background-sm
Search
3

Updates found with 'manual switch'

Page  1 1

Updates found with 'manual switch'

Preset Production Counters Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL Production CountersProduct Features: Din sized enclosure for panel mounting.Wide Voltage rangeFront / Rear reset facility provided.Hold / Restart options (selectable) during power failure.Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etcOver-voltage protectionCT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value.Preset Counts can be programmed with the help of thumbwheel switchH3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set valueInput sensitivity – programmable (1-100Hz)Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.Dimensions: Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D)Applications: Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many moreOrdering Information: Model Function Source Voltage Range Output Data SheetRegularCT-5 Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay Click HereH3CT-5U Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay
Send Enquiry
Read More
Programmable Anunciators Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL for Alarm AnunciatorsProduct Features: Sleek, light weight, ABS enclosureSuper bright, Red color SMD, LED for fault indicationsTest / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.Multiple units terminals can be connected in parallel to achieve more windowsEach window can be programmed for fault inputs as NO or NC and output as alarm or tripAbove program can be locked by removing the short link across specified terminalsOver voltage protectionBasic Models: M2-2 / M2-4 / M2-6 / M2-8Advanced Models: M2-12 / M2-16 / M2-24Available in 12, 16 and 24 windows respectivelyAvailable in wide auxiliary voltage range of 85-270V AC/DC.Advanced Models with additional features: M2-12R / M2-16R / M2-24RRS485 output signals are available for displaying Fault and healthy status of each window.Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window.Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D)Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm, M2-12, M2-16, M2-24: 285 x 181mm(W x H)Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc.Ordering Information: Model No. of Windows Function Source Voltage Output Input Data SheetRegularM2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click HereM2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputsM2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputsM2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputsM2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click HereM2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputsM2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputsOptionalM2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact UsM2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputsM2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputsM2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputsM2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputsM2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputsM2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs
Send Enquiry
Read More
Page 1 0.9