http://WWW.SVESLUDHIANA.IN
SVES 59d3c289767a2d0b30e5c34d False 83 57
OK
background image not found
Found Update results for
'window'
5
Programmable Anunciators Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL for Alarm Anunciators Product Features: Sleek, light weight, ABS enclosure Super bright, Red color SMD, LED for fault indications Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available. Multiple units terminals can be connected in parallel to achieve more windows Each window can be programmed for fault inputs as NO or NC and output as alarm or trip Above program can be locked by removing the short link across specified terminals Over voltage protection Basic Models: M2-2 / M2-4 / M2-6 / M2-8 Advanced Models: M2-12 / M2-16 / M2-24 Available in 12, 16 and 24 windows respectively Available in wide auxiliary voltage range of 85-270V AC/DC. Advanced Models with additional features: M2-12R / M2-16R / M2-24R RS485 output signals are available for displaying Fault and healthy status of each window. Repeat relay cards having 8 (C-NO) outputs can be supplied on order to connect the main unit to 1, 2 or 3relay cards (as required) in a daisy chain arrangement and achieve one output for each window. Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: M2-2, M2-4, M2-6, M2-8: 74 x 143 x 78mm, M2-12, M2-16, M2-24: 291 x 186.5 x 79mm (W x H x D) Repeat relay card: 195x90x59mm (W x H x D) Cut-out: M2-2, M2-4, M2-6, M2-8: 69 x 141 x 75mm, M2-12, M2-16, M2-24: 285 x 181mm(W x H) Applications: Panels – Generator, Distribution, MCC, Compressor, Fire annunciation, Boiler, Weigh Bridges, Process control, etc. Ordering Information: Model No. of Windows Function Source Voltage Output Input Data Sheet Regular M2-2 2 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 2 potential free (Zero Volt) fault input Click Here M2-4 4 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 4 potential free (Zero Volts) fault inputs M2-6 6 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 6 potential free (Zero Volts) fault inputs M2-8 8 windows Programmable Fault annunciation 85-270V AC / DC, 18-90V AC / DC 2 relays 1 c/o (C-NO), (trip / Alarm) 8 potential free (Zero Volts) fault inputs M2-12 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs Click Here M2-16 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs Optional M2-1 1 windows Programmable Fault annunciation 110VAC 1 c/o (NC-C-NO) 1 fault input (12V AC / DC - 240VAC / 220V DC) Contact Us M2-12 12 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16 16 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 16 potential free (Zero Volts) fault inputs M2-24 24 windows Programmable Fault annunciation 24V DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 24 potential free (Zero Volts) fault inputs M2-12R 12 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-16R 16 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs M2-24R 24 windows Programmable Fault annunciation 85-270V AC / DC 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) 12 potential free (Zero Volts) fault inputs
Fault Annunciators Make EAPL 4 window 6 window 8 window 16 window 24 window With 1 YEAR warranty EAPL IN LUDHIANA EAPL SVES
Preset Production Counters Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL Production Counters Product Features: Din sized enclosure for panel mounting. Wide Voltage range Front / Rear reset facility provided. Hold / Restart options (selectable) during power failure. Input signal from proximity switch ( NPN / PNP type) or Potential free (zero volt) signal from limit switch, relay o/p etc Over-voltage protection CT-5: Digital, single window 5 digit 7 segment red LED display with up counting for process value. Preset Counts can be programmed with the help of thumbwheel switch H3CT-5U : Digital, single window 5 digit 7 segment red LED display with up counting for both process value and set value Input sensitivity – programmable (1-100Hz) Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal. Dimensions: Overall: CT-5 – 72 x 72 x 128mm, H3CT-5U – 48 x 48 x 115mm (W x H x D) Applications: Paper board counting, bag counting, bottle counting, relay change over counting, breaker panels, stroke counting in granite cutting m/c and many more Ordering Information: Model Function Source Voltage Range Output Data Sheet Regular CT-5 Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay Click Here H3CT-5U Preset counter (LED Display), 5 digits 85-270V AC/DC 1-99999counts 1 c/o, 5A Relay
Maximum Demand Controller Supplier in Ludhiana Call@ +91 9988557000 We are the leading supplier of all Electrical and Electronic automation product in Punjab. We are the authorised dealer of EAPL Maximum Demand Controller. Product Features: Measurement of basic, power, energy and demand parameters. On-site programmable PT and CT ratios. High brightness LED display (alpha numeric for parameter, numeric for value). Automatic CT reverse correction for energy and demand. Programmable demand techniques : block / sliding window. Programmable demand parameters : Apparent / Active power. Programmable demand range : Kilo / Mega. Programmable Alarm / hysterisis settings. Program RTC time to match EB meter's clock. For EMS-15C : Max. Demand Controller = Max. demand indicator + Relay module (4 relay) (RR-4). 4 control outputs for alarm and trip settings. Dimensions: Overall:EMS 15, EMS 15C 96 x 96 x 117mm (W x H x D) , RR-4: 195x90x59mm(WxHxD) Cutout: 92 x 92mm(W x H) Applications: In-comer distribution panels
G / E-Series Digital Monitoring devices You are here HOME » PRODUCTS » MONITORING & MOTOR PROTECTION DEVICES » G / E-SERIES Product Features: Front button for resetting in manual mode External potential free (zero volt /no voltage) terminal contacts for auto mode. LED indication for relay status Window displays the type of fault that has occurred during unhealthy condition Trip delay time and limits for each parameter can be set digitally All programs can be locked by removing short link across specified terminals Unwanted parameters can be by-passed as per user's choice. Relay can be configured to have NO or NC status during healthy condition Unit will retain fault till accepted in manual mode PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs. Displays all the 3 phase voltages in a scrolling fashion during healthy condition. PVMD – Panel / Flush mounting, PVMD-G Din Rail mounting PVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current) Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition. User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current. User can set the in-rush time delay. Terminals to connect all the 3 phase CTs are provided. CT primary can be programmed up to 2500 in steps of 5. CT secondary will be factory set for 5. PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mounting Din sized enclosure with Auto / manual Switch Dimensions: Overall: PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G, – 76 x 78 x 115mm (W x H x D) Cut-out: PVMD, PVIMD– 92 x 92mm (W x H) Applications: Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators, etc Ordering Information: Model Function Input voltage Output Data Sheet PVMD Phase Voltage Monitoring Device 415V AC 3phase, 4 wire, Self powered 1 c/o, 10A Click Here PVMD - G Phase Voltage Monitoring Device PVIMD Phase Voltage Current Monitoring Device PVIMD - G Phase Voltage Current Monitoring Device
1
false